Авторизоваться | регистр
дома > Центр продуктов > Coating & Film Applicators > Hot Melt Adhesive Coating Tester

Hot Melt Adhesive Coating Tester

    Hot Melt Adhesive Coating Tester

    The benchtop Hot Melt Adhesive Coating Tester is a compact device for hot melt coating and laminating as well as surface coating of various substrates. The glue tank is thermostatically heated from room temperature to 180°C, with a coating width of 300 mm, mechanical speed of 100-800 mm/min, and coating accuracy better than ±2 μm. Its aluminum alloy benchtop design is simple to operate, making it ideal for hot melt adhesive bench-scale R&D.
  • делиться:
  • контакт Онлайн-запрос
  • почтовый ящик:anmt_test@126.com

Product Introduction
The benchtop experimental coating machine is a compact device designed for hot melt adhesive coating and laminating, as well as for surface coating of various substrates. It is user-friendly while delivering precision and consistency comparable to production requirements. The glue tank is thermostatically controlled, making it ideal for bench-scale trials involving hot melt adhesives and other materials requiring heated coating. The device features a compact structure, comprehensive functionality, and ease of operation—even users without prior experience can quickly master it.


Key Features
Compact Benchtop Design: Overall dimensions of just 1100 mm × 550 mm × 600 mm with an aluminum alloy main body, occupying minimal bench space.
High-Precision Coating: Coating accuracy better than ±2 μm, coating length accuracy ±1 mm, and roller runout ≤2 μm, ensuring consistency and repeatability for lab samples.
Thermostatic Glue Tank Heating: Glue tank temperature adjustable from room temperature to 180°C, meeting the melting and coating requirements of various hot melt adhesives.
Continuous Coating and Laminating: Supports continuous coating with integrated laminating function, enabling single-pass coating and bonding for hot melt lamination process studies.
Adjustable Winding Tension: Unwinding tension manually adjustable from 5-50 N, winding tension 5-50 N, with automatic AC motor winding for stable substrate transport.
Easy Operation: Push-button control, manual web guiding, and manual cutting (optional cutting frame), requiring minimal training to operate.


Technical Specifications

Parameter

Specification

Power supply

Single-phase AC 220 V ±10% (110 VAC customizable); 50/60 Hz; 5 kW

Air supply

0.5-0.8 MPa compressed air

Operating environment

Temperature 25±3°C; humidity 30-90% RH; no vibration, no EMI

Coating type

Continuous coating

Guide roller width

320 mm

Max. substrate width

300 mm

Max. coating width

300 mm

Mechanical speed

100-800 mm/min

Coating accuracy

Better than ±2 μm (within 5 mm of edge)

Coating length accuracy

±1 mm

Coating roller runout

≤2 μm

Coating roller diameter

100 mm

Max. unwinding diameter

300 mm

Winding diameter

200 mm

Unwinding tension

5-50 N (manually adjustable)

Winding tension

5-50 N (manually adjustable)

Winding method

AC motor automatic winding

Metering method

Coating doctor blade

Web guiding

Manual

Glue tank heating temp.

Room temp. to 180±5°C

Laminating function

Yes

Cutting method

Manual cutting (cutting frame optional)

Machine structure

Benchtop

Control

Push-button

Main material

Aluminum alloy

Overall dimensions (L×W×H)

1100 mm × 550 mm × 600 mm


FAQ
1. Glue tank not heating or heating slowly
Temperature set too low, heating element damaged, or temperature probe malfunction. Reset temperature; service heating assembly and sensor.
2. Hot melt adhesive not fully melted
Set temperature insufficient, adhesive contains impurities, or tank has heavy carbon deposits. Increase set temperature; clean residual glue and carbon from tank.
3. Uneven overall coating thickness
Fluctuating transport speed, coating roller gap misalignment, or substrate skewing. Calibrate roller gap; stabilize transport speed; realign substrate.
4. Localized adhesive starvation or break
Blocked glue path, damp/agglomerated adhesive particles, or poor feed. Clear glue channels; use dry, qualified hot melt adhesive.
5. Edge overflow, coating beyond width
Coating width exceeds specification, temperature too high making glue too thin, or doctor blade gap too large. Lower temperature; fine-tune doctor blade gap.
6. Unwinding/winding misalignment
Inappropriate tension or poor manual web guiding; glue build-up on rollers. Adjust unwind/wind tension; correct web guiding promptly.
7. Inconsistent winding tightness
Unstable winding tension or mismatched speed. Synchronize speed; fine-tune winding tension.
8. Weak lamination bond
Insufficient coating amount, low hot melt temperature, or inadequate lamination pressure. Raise temperature appropriately; increase coating amount and lamination pressure.
9. Excessive operating noise
Transmission components lacking lubrication, worn bearings, or debris on rollers. Regularly lubricate; clean debris; inspect bearings.
10. Insufficient air pressure affecting lamination
Inadequate air supply pressure, air hose leak, or loose fittings. Check compressor pressure; tighten air hose fittings.
11. Buttons unresponsive, parameter failure
Poor wiring contact or control panel damp. Power cycle; check internal wiring.


After-Sales Service
Thank you for your inquiry. Shandong Annimet Instrument Co., Ltd., established in 2007, has dedicated nearly two decades to the R&D, production, and sales of quality testing instruments. We regard product quality as the lifeblood of our enterprise and pursue excellence in every product developed. Annimet Instrument will consistently provide the tools for your ideas and creativity. Should you have any questions, please feel free to contact our customer service team.

Hot Melt Adhesive Coating Tester



Онлайн-сообщение

Пожалуйста, введите действительный адрес электронной почты.
код проверки Не может быть пустым

Связанные продукты

Нет результатов поиска!
400-9933-057

Shandong Annimet Instruments Co., Ltd., established in 2007, is a professional manufacturer integrating R&D, production, and sales of laboratory testing instruments and sample preparation equipment. With nearly two decades of industry experience, we are committed to delivering reliable quality testing solutions to clients worldwide.

Contact Us

Contact: +86 400-9933-057 

Company Address: Factory Building 105, No. 155, Xinmao Qilu Science and Technology City, No. 299 Zidong Avenue, Tianqiao District, Jinan City, Shandong Province

E-mail: anmt_test@126.com

Fax: +86 0531-88092218

Copyright ©  2026 Shandong Annimet Instruments Co., Ltd.  All rights reserved

Карта сайта

Этот веб-сайт использует файлы cookie, чтобы обеспечить вам максимально эффективное использование нашего веб-сайта.

Принимать отклонять